The area of the window well shall allow the emergency escape and rescue opening to be fully opened.
Egress window well code.
Egress ladders and or steps are required on window wells deeper than 44 and.
Windows can be of various total size but their free areas when open must be at least 5 7 square feet.
Width x projection egress ladders and or steps.
2009 international fire code section 1029 emergency escape and rescue.
Egress window well code requirements.
This guide reviews egress window requirements for basements and upper floors as well as the different types of egress windows.
The horizontal dimensions of the window well shall provide a minimum net clear area of 9 square feet 0 84 m2 with a minimum horizontal projection and width of 36.
The distance from the egress window to the back of the egress well must be at least 36 the minimum area of the egress well must be 9 square feet.
Big savings on the exceptional line of wellcraft kits including the 2060 2062 6700 and the 5 section 5600.
Taking its name from the act of departure an egress window is designed to provide an emergency means of leaving a dwelling.
The area of a window well shall not be less than 9 square feet with a horizontal length width of no less than 36 inches.
On select wellcraft complete egress window well kits.
Where the sill height is below grade it shall be provided with a window well in accordance with section r310 2 3.
When the sill height of an egress window is located below grade common for egress windows provided for a basement a window well must be provided.
Window well experts united states washington.
To ensure you install the right egress for your basement we ll break down the residential window well code requirements you ll need to abide by.
Egress window and well requirements.
An emergency escape and rescue opening with a finished sill height below the adjacent ground level shall be provided with a window well in accordance with sections 1029 5 1 and 1029 5 2.
The egress well must not interfere with the egress window fully opening.
The horizontal area of the window well shall be not less than 9 square feet.
The minimum horizontal area of the window well shall be 9 square feet 0 9 m2 with a minimum horizontal projection and width of 36 inches 914 mm.
The sill must be no higher than 44 inches from the ground.
Building codes in many areas require egress windows as a matter of home safety.
Window wells required for emergency escape and rescue shall have horizontal dimensions that allow the door or window of the emergency escape and rescue opening to be fully opened.