Each row going across is a different size and type of conduit either emt imc or galvanized pipe rigid metal conduit rmc.
Emt pipe wire capacity.
The pvc conduit fill table.
Find the type of conduit that you want to use in table 4.
The results show the allowable number of wires for each size type of conduit and wire based on the 2020 nec code.
If you have a fixed conduit type and size.
Welcome to the conduit fill calculator website.
Conduit cable fill chart this chart for conduit size for cable is based on the 2017 nec and uses common conduit types and wires.
This online conduit fill calculator is compatible with the us national electrical code nec.
The amount of wire fill inside a conduit must be configured properly to prevent overheating of the wire which is why conduit fill tables are very important.
However inch emt has a maximum fill of 0 213 which is greater than the 0 138 calculated fill.
For example to use emt type conduit with the previously calculated total fill of 0 138 look in the emt column of table 4.
If you re using electrical metal tubing emt conduit you ll see that the closest size that you need is a 1 in conduit which gives you a 39 fill.
Each column going up and down is a different gauge of wire.
Using electrical conduit is the required method of protecting electrical wires in exposed situations where nm cable cannot be used.
While using a wire fill table for electrical conduit it is best to size the conduit up to the next incremental size to be sure the conduit is not overfilled and it will make pulling in.
Inch conduit is the correct size for this application.
Electrical conduit whether it be rigid metal emt rigid plastic pvc or flexible metal fmc is limited as regards the maximum number of electrical wires that can be run inside the conduit.
How to use a conduit fill chart the fill chart above allows you to determine how many wires can go inside a given conduit and not exceed a 40 fill rate.
Conduit fill calculator conduit fill is the percent of area inside the conduit taken up by the cable s.
Helps determine the proper wire size for an electrical circuit based on the voltage drop and current carrying capacity of an electrical circuit.
Inch emt has a maximum fill of 0 122 which is too small.
The possible wire gauges go from 14 awg to 750 mcm and from conduit trade sizes of 1 2 inches to 4 inches.
We hope to provide you with the best online conduit fill calculator as well as all relevant information regarding conduits conduit fill conduit accessories and more.
Emt rnc pvc 40 rnc pvc 80 rmc rigid grc imc ent flex lfmc rnc type db 60 rnc type eb 20.